Page 112 FTDX1200 Operating Manual

MENU MODE Cont'd

Previous Page    Index of Topics    Table of Contents    Index of Pages    Next Page

MENU ITEM DETAILS



AGC GROUP

001 FAST DELAY
Function: Sets the delay time for the AGC FAST mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 500 msec


002 MID DELAY
Function: Sets the delay time for the AGC MID mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 1000 msec


003 SLOW DELAY
Function: Sets the delay time for the AGC SLOW mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 4000 msec


004 SLOPE
Function: Select the gain curve of the AGC smplifier.
Available Values: NORMAL or SLOPE
Default Setting: NORMAL

NORMAL: The AGC output level will follow a linear response to the antenna input level, while AGC is activated.

SLOPE: The AGC output level will increase at 1/10 the rate of the antenna input level, while AGC is activated.


End of "AGC Group


DISPLAY GROUP

005 MY CALL
Function: Programs your Call Sign.
Available Values: Max 12 characters
Default Setting: FTDX1200


006 MY CALL TIME
Function: Programs the display time of your Call Sign.
Available Values: OFF ~ 5 sec
Default Setting: 1 sec


007 VFO COLOR
Function: Selects the VFO-A frequency background color.
Available Values: BLUE, SKY BLUE, GREEN, PURPLE, RED, ORANGE, GRAY, BLACK
Default Setting: BLUE


008 TFT LAYOUT
Function: Set the positions of the frequency display and meter display.
Available Values: TYPE 1, TYPE 2
Default Setting: TYPE 1

TYPE 1: Displays the frequency display at the top of the FTF display.

TYPE 2: Displays the frequency display below the S/PO meter and the DSP display.


009 DIMMER LED
Function: Sets the indicator illumination level.
Available Values: 1 or 2
Default Setting: 2

Adjusts the illumination level of the indicator located on the above of the Main Tuning Dial knob. You may observe the effects of the changes as you adjust the level setting. The higher the setting, the brighter the illumination becomes.


010 DIMMER TFT
Function: Setting of the TFT display brightness level.
Available Values: 0 ~ 15
Default Setting: 8


011 BAR DISPLAY SELECT
Function: Selects one of three parameters to be viewed on the Tuning Offset Indicator.
Available Values: CLAR or CW TUNE or µTUNE
Default Setting: CW TUNE

CLAR: Displays relative Clarifier offset.

CW TUNE: Displays relative tuning offset between the incoming signal and transmitted frequency while in CW operation.

µTUNE: Displays the peak position of the optional µTUNE filter.


012 METER TYPE SELECT
Function: Selects the meter display type.
Available Values: ANALOG or BAR
Default Setting: BAR

ANALOG: Displays relative Clarifier offset.

BAR: Displays relative tuning offset between the incoming signal and transmitted frequency while in CW operation.


013 BAR MTR PEAK HOLD
Function: Selects the peak hold time of the BAR meter.
Available Values: OFF, 0.5, 1.0, 2.0, sec
Default Setting: OFF


014 ROTATOR START UP
Function: Selects the staring point of your rotator controller's indicator needle.
Available Values: 0, 90, 180, or 270 degrees
Default Setting: 0 degrees

ADVICE: If the optional Antenna Rotator is not connected, this adjustment has no effect.


Cont'd Next Page Menu Item Details "Display Group"

Cont'd Next Page "Menu Mode"

Previous Page    Index of Topics    Table of Contents    Back to Top    Index of Pages    Next Page